D-PB-1

STANDARD DETAILS FOR CONCRETE PIPE INSTALLATION
D-PB-1

(Click image to open PDF)

Latest Revision Note

03/01/2023    REVISED GENERAL NOTE (G1).

Related Standard Drawings

DRAWING DESCRIPTION REMARKS
D-PB-3 INDUCED TRENCH SOIL EMBANKMENT FOR PIPE CULVERT INSTALLATION SEE FOR MINIMUM CONSTRUCTION COVER DEPTHS
D-PE-1 TYPE "A" CONCRETE ENDWALLS FOR ROUND PIPE (PIPE SIZES 36" TO 78", ALL SKEWS, 2:1 SLOPE) CROSS DRAIN ENDWALLS PLACED OUTSIDE THE CLEAR ZONE MAY USE TYPE A
D-PE-4 STRAIGHT CONCRETE ENDWALLS (PIPE SIZES 18" TO 30") CROSS DRAIN ENDWALLS PLACED OUTSIDE THE CLEAR ZONE MAY USE STRAIGHT HEADWALL
D-PE-9 TYPE "B" CONCRETE ENDWALLS FOR ROUND AND SIDE TAPERED INLETS (PIPE SIZES 15" TO 78", ALL SKEWS, 2:1 AND 4:1 SLOPES) CROSS DRAIN ENDWALLS PLACED OUTSIDE THE CLEAR ZONE MAY USE TYPE B
D-PE-9A TYPE "B" CONCRETE ENDWALLS FOR ROUND INLETS, DETAILS & QUANTITIES (PIPE SIZES 15" TO 78", ALL SKEWS, 2:1 AND 4:1 SLOPES) CROSS DRAIN ENDWALLS PLACED OUTSIDE THE CLEAR ZONE MAY USE TYPE B
D-PE-9B TYPE "B" CONCRETE ENDWALLS FOR SIDE TAPER INLETS, DETAILS & QUANTITIES (PIPE SIZES 15" TO 78", ALL SKEWS, 2:1 AND 4:1 SLOPES) CROSS DRAIN ENDWALLS PLACED OUTSIDE THE CLEAR ZONE MAY USE TYPE B
D-PE-9C TYPE "B" CONCRETE ENDWALLS, BILL OF STEEL FOR CONCRETE PIPES (PIPE SIZES 15" TO 78", ALL SKEWS, 2:1 SLOPE) CROSS DRAIN ENDWALLS PLACED OUTSIDE THE CLEAR ZONE MAY USE TYPE B
D-PE-9D TYPE "B" CONCRETE ENDWALLS, BILL OF STEEL FOR CONCRETE PIPES (PIPE SIZES 15" TO 78", ALL SKEWS, 4:1 SLOPE) CROSS DRAIN ENDWALLS PLACED OUTSIDE THE CLEAR ZONE MAY USE TYPE B
D-PE-9E TYPE "B" CONCRETE ENDWALLS, BILL OF STEEL FOR STEEL PIPES (PIPE SIZES 15" TO 78", ALL SKEWS, 2:1 SLOPE) CROSS DRAIN ENDWALLS PLACED OUTSIDE THE CLEAR ZONE MAY USE TYPE B
D-PE-9F TYPE "B" CONCRETE ENDWALLS, BILL OF STEEL FOR STEEL PIPES (PIPE SIZES 15" TO 78", ALL SKEWS, 4:1 SLOPE) CROSS DRAIN ENDWALLS PLACED OUTSIDE THE CLEAR ZONE MAY USE TYPE B
D-PE-15A TYPE "U" CROSS DRAIN ENDWALL FOR 15" PIPE (FOR 3:1, 4:1 & 6:1 SLOPES) FOR END WALL GEOMETRY
D-PE-18A TYPE "U" CROSS DRAIN ENDWALL FOR 18" PIPE (FOR 3:1, 4:1 & 6:1 SLOPES) FOR END WALL GEOMETRY
D-PE-24A TYPE "U" CROSS DRAIN ENDWALL FOR 24" PIPE (FOR 3:1, 4:1 & 6:1 SLOPES) FOR END WALL GEOMETRY
D-PE-30A TYPE "U" CROSS DRAIN ENDWALL FOR 30" PIPE WITH STEEL PIPE GRATE (FOR 3:1, 4:1 & 6:1 SLOPES) FOR END WALL GEOMETRY
D-PE-36A TYPE "U" CROSS DRAIN ENDWALL FOR 36" PIPE WITH STEEL PIPE GRATE (FOR 3:1, 4:1 & 6:1 SLOPES) FOR END WALL GEOMETRY
D-PE-42A TYPE "U" CROSS DRAIN ENDWALL FOR 42" PIPE WITH STEEL PIPE GRATE (FOR 3:1, 4:1 & 6:1 SLOPES) FOR END WALL GEOMETRY
D-PE-48A TYPE "U" CROSS DRAIN ENDWALL FOR 48" PIPE WITH STEEL PIPE GRATE (FOR 3:1, 4:1 & 6:1 SLOPES) FOR END WALL GEOMETRY
D-PE-99 TYPE "U" CROSS DRAIN ENDWALL DETAILS, PIPE GRATE & SKEWED CONNECTION FOR GRATE DETAILS
D-SEW-1A TYPE "SAFETY" SIDE DRAIN ENDWALL WITH STEEL PIPE GRATE, FOR 15" THRU 48" PIPES, 6:1 SLOPE D-SEW- SERIES STANDARD DRAWINGS WITH SAFETY GRATE
D-SEW-12D TYPE "SAFETY" SIDE DRAIN ENDWALL WITH STEEL PIPE GRATE, FOR 18" PIPES, 12:1 SLOPE ALL MEDIAN CROSSOVER SIDE DRAINS (LONGITUDINAL) PLACED UNDER MEDIAN OPENINGS REQUIRE SAFETY ENDWALLS AS SHOWN
D-SEW-SERIES Pipe Culverts and Endwalls Standard Drawings ALL SIDE DRAINS (PARALLEL) PLACED UNDER A SIDE ROAD, DRIVEWAY, OR FIELD ENTRANCE, ETC. THAT INTERSECT A MAINLINE ROADWAY, REQUIRE SAFETY ENDWALLS AS SHOWN
S-CZ-1 CLEAR ZONE CRITERIA ALL CULVERT ENDWALLS LOCATED WITHIN THE CLEAR ZONE

Related Item Numbers

ITEM NO. U/M DESCRIPTION
607-03.02 L.F. 18" CONCRETE PIPE CULVERT (CLASS III)
607-03.03 L.F. 18" CONCRETE PIPE CULVERT (CLASS IV)
607-03.04 L.F. 18" CONCRETE PIPE CULVERT (CLASS V)
607-05.02 L.F. 24" CONCRETE PIPE CULVERT (CLASS III)
607-05.03 L.F. 24" CONCRETE PIPE CULVERT (CLASS IV)
607-05.04 L.F. 24" CONCRETE PIPE CULVERT (CLASS V)
607-06.02 L.F. 30" CONCRETE PIPE CULVERT (CLASS III)
607-06.03 L.F. 30" CONCRETE PIPE CULVERT (CLASS IV)
607-06.04 L.F. 30" CONCRETE PIPE CULVERT (CLASS V)
607-07.02 L.F. 36" CONCRETE PIPE CULVERT (CLASS III)
607-07.03 L.F. 36" CONCRETE PIPE CULVERT (CLASS IV)
607-07.04 L.F. 36" CONCRETE PIPE CULVERT (CLASS V)
607-08.02 L.F. 42" CONCRETE PIPE CULVERT (CLASS III)
607-08.03 L.F. 42" CONCRETE PIPE CULVERT (CLASS IV)
607-08.04 L.F. 42" CONCRETE PIPE CULVERT (CLASS V)
607-09.02 L.F. 48" CONCRETE PIPE CULVERT (CLASS III)
607-09.03 L.F. 48" CONCRETE PIPE CULVERT (CLASS IV)
607-09.04 L.F. 48" CONCRETE PIPE CULVERT (CLASS V)
607-10.02 L.F. 54" CONCRETE PIPE CULVERT (CLASS III)
607-10.03 L.F. 54" CONCRETE PIPE CULVERT (CLASS IV)
607-10.04 L.F. 54" CONCRETE PIPE CULVERT (CLASS V)
607-11.03 L.F. 60" CONCRETE PIPE CULVERT (CLASS IV)
607-11.04 L.F. 60" CONCRETE PIPE CULVERT (CLASS V)
607-11.05 L.F. 60" CONCRETE PIPE CULVERT(CLASS IV)JACKED-IN-PLACE
740-10.03 S.Y. GEOTEXTILE (TYPE III)(EROSION CONTROL)

Archived Standard Drawings

DATES OF EACH ARCHIVED DRAWINGS ( THE INITIAL STANDARD DRAWING IS BOLD )
07-12-2007 | 06-01-2009 | 02-01-2012 | 08-21-2012 | 01-02-2013 | 03-16-2017 | 06-28-2019 | 11-30-2020 | 03-04-2021 | 03-01-2023

If you find any mistakes, missing information or have a question, contact:
TDOT CADD Support
1200 James K. Polk Building
Nashville, TN 37243-1402
TDOT.CADDSupport@tn.gov

This Page Last Updated: April 17, 2023 at 11:31 AM